Further Refine if Needed.
You have Selected:
Quick Category Search
Signal Input & Function:
Applications:
Price:

MICRON TRANSMITTERS | DIN Rail Mount

Micron DIN Rail Transmitters: MLT Series: RS232/RS485 & 4-20ma | MLTE Series: Ethernet & 4-20mA | MLTS Series: Serial to Analog

TRANSMITTER SIGNAL INPUT & FUNCTION GUIDE
MLT MODELS
MLTE MODELS
 Quad 4-20mA Loop Splitter
 MQLS  
 Serial Data Input (Serial to Analog Converter)
 MLT-S6  MLTE-S6
 DC Voltage or Current
 MLT-DC  MLTE-DC
 AC RMS Voltage or Current
 MLT-RM MLTE-RM
 Process Voltage or Current
 MLT-P  MLTE-P
 Strain Gauge or Potentiometer Follower
 MLT-SG  MLTE-SG
 Load Cell & Micro-Volt Signals
 MLT-WM  MLTE-WM
 Thermocouple (Types J,K,T,E,N,R,S)
 MLT-TC  MLTE-TC
 RTD Temperature
 MLT-TD  MLTE-TD
 Resistance in Ohms
 MLT-R  MLTE-R
 Frequency, Rate, Speed
 MLT-FR  MLTE-FR
 Pulse Input Totalizer
 MLT-FR  MLTE-FR
 Process Signal Totalizer
 MLT-FR  MLTE-FR
 Sum, Difference, Ratio, Product of 2 inputs.
 MLT-FR  MLTE-FR
 ON / OFF Duty Cycle
 MLT-FR  MLTE-FR
 Stopwatch Timing for Single Events
 MLT-FR  MLTE-FR
 Average Time of Periodic Events
 MLT-FR  MLTE-FR
 AC Phase Angle and Power Factor
 MLT-FR  MLTE-FR
 Quadrature Position or Rate
 MLT-QD  MLTE-QD

Downloadable Owners Manuals

For Micron Digital Panel Meters, Counters, Remote Displays, Transmitters
Download our latest manuals in and print yourself a full-size copy.
PDF format
Call Micron for older manuals.
Owner manuals Micron MM50 Series Electronics

Micron 1/8 DIN Panel Mount Instruments

Micron DIN Rail Mount Transmitters

*1 Applies to MLTA & MLTM transmitters, analog input, as these are the same as MLT transmitters.
*2
Applies to MLTA & MLTM transmitters, pulse input, as these are the same as MLT transmitters.

Micron Communication & Datalogging Manuals

Non-Micron Meters

MAGNA Large Digit Displays

Micron Legacy Products

Instruction Sheets for 1/8 DIN Size Meter Accessories

Here are some of the most Frequently Asked Questions about our DIN-Rail Products.
If you don't find an answer to your question, send us an email.

Micron MLT Series RS232/RS485 & 4-20 mA transmitters provide an isolated, digitally addressable serial data output, an isolated 16-bit, 4-20 mA, 0-20 mA or 0-10V analog output, plus dual solid state AC/DC relays. The Modbus protocol is fully supported.

Micron MLT DIN Rail Transmitters, 4-20 mA & RS232/RS485 Serial Data Outputs
Same High Performance, Signal Conditioning and programmable features as Micron Digital Panel Meters, Counters & Timers.

Features

  •  4-20 mA, 0-20 mA, 0-10V or -10V to +10V transmitter output, 16 bits, isolated
  • RS232 or RS485 serial data output, isolated, Modbus or Custom ASCII protocol
  • Dual 120 mA solid state relays for alarm or control, isolated
  • Analog output resolution 0.0015% of span (16 bits), accuracy ±0.02% of span
  • 5V, 10V or 24V dc transducer excitation output, isolated (most models)
  • Universal 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac power
  • DIN rail housing with detachable screw-clamp connectors
  • Easy transmitter setup using PC-based Instrument Setup Software
  • Available with signal conditioning for most industrial analog or pulse transducer signals

Micron MLT Series Transmitter Description
 
MLT series DIN rail transmitters & signal conditioners
can be interfaced to a wide range of sensors and transducers using one of seven available plug-in signal conditioner boards. The transmitters duplicate the high performance (high accuracy, high read rate) and extensive programmable features of Micron 1/8 DIN digital panel meters, counters and timers. They utilize the same signal conditioners boards, much of the same firmware, and the same Windows-based free Instrument Setup Software. They come in a compact DIN rail mount package with detachable screw-clamp connectors for easy wiring.

The Micron MLT series transmitters accessible from this page include a 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V analog output (isolated, user selectable), an RS232 or RS485 serial data interface (isolated, user selectable), and dual 120 mA solid state AC/DC relays (isolated). An isolated 5, 10 or 24 Vdc transducer excitation output is included with all models other than those with a temperature or AC RMS signal conditioner.



For use on a local area network (LAN)
, up to 30 LT series transmitters can be jumpered for RS485 and be daisy chained to a meter or counter with the  Ethernet-to-RS485 converter board. As an alternative, Micron's MLTE series Ethernet transmitters can be connected directly to a LAN via an Ethernet cable. In both cases, setup is easily achieved using Instrument Setup Software for node discovery and setup of each transmitter.


Micron MLTE Series Ethernet & 4-20 mA transmitters can be interfaced to an Ethernet network while also providing an isolated 16-bit, 4-20 mA, 0-20 mA or 0-10V analog output plus dual solid state AC/DC relays. The Modbus TCP protocol is fully supported

Micron MLTE DIN Rail Transmitters, 4-20 mA & Ethernet Serial Data Outputs
Same high performance, signal conditioning and programmable features as Micron Meters digital panel meters, counters & timers.

Features

  • Ethernet serial data interface, isolated, Modbus TCP or Laurel ASCII protocol
  • 4-20 mA or 0-10V transmitter output, jumper selectable, isolated
  • Analog output resolution 0.0015% of span (16 bits), accuracy ±0.02% of span
  • Dual 120 mA solid state relays for alarm or control, isolated
  • 5V, 10V or 24V dc transducer excitation output, isolated (most models)
  • Universal 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac power
  • DIN rail housing with detachable screw-clamp connectors
  • Easy network setup using PC-based Node Manager Software and built-in Web Server
  • Easy transmitter setup using PC-based Instrument Setup Software
  • Signal conditioning for most industrial analog or pulse transducer signals


Micron MLTE Series Transmitter Product Line Overview

Micron MLTE Series DIN rail transmitters & signal conditioners come with an Ethernet interface (isolated), a 4-20 mA or 0-10V analog output (isolated), dual 120 mA solid state AC/DC relays (isolated), and a transducer excitation output (isolated, models other than for temperature or AC RMS).

Micron MLTE transmitters can be interfaced to a wide range of sensors and transducers using one of seven seven available signal conditioner boards. The transmitters duplicate the high performance (high accuracy, high read rate) and extensive programmable features of Micron 1/8 DIN digital panel meters, counters and timers. They utilize the same signal conditioner boards, much of the same firmware, and the same Windows-based Instrument Setup Software. They come in a compact DIN rail mount package with detachable screw-clamp connectors for signal and power.


MLTE transmitters can be connected directly to a Local Area Network (LAN) via an Ethernet cable and allow remote readings over the Internet. Modbus TCP and the simpler Custom ASCII communication protocols are fully supported. Please see our Modbus Communications Manual and our Serial ASCII Communications Manual. Node discovery and transmitter setup are by means of Instrument Setup Software, which is downloadable and free of charge. Additonal Node Manager Software, which is also downloadable and free of charge, provides utilities to configure each node, such as naming the node, entering email addresses for alarm notification and data requests, selecting the node's time zone for time-stamping of streaming data, setting communication parameters, setting static IP addresses if required, and updating node firmware.



Micron MLTS RS232/RS485 input transmitters and MLTSE Ethernet input transmitters are serial-to-analog converters which convert serial data to an isolated, 16-bit, 4-20 mA, 0-20 mA or 0-10V analog output. These converters can extract readings from long data strings.

Inputs for MLT andM LTE Series transmitters can be analog signals (AC voltage or current, DC voltage or current, strain gauge, load cell, thermocouple, RTD, resistance), pulse inputs (rate & frequency, totalizing, quadrature position or rate, process time, sum, difference or ratio of two inputs, AC phase angle or power factor, duty cycle), or a serial data (RS232 or RS485) input.

Micron DIN Rail Transmitter Case
For Micron Transmitter Models MLT, MLTE, MLTS, MLTSE, MQLS.

Key Features

  • Mounts to 35 mm rail per DIN EN 50022
  • 129 mm deep x 104 mm high x 22.5 mm wide
  • Rugged black poly-carbonate housing material
  • Detachable screw clamp connectors meet VDE / IEC / UL / CSA standards
  • For Micron transmitter series MLT, MLTE, MLTS, MLTSE
  • Weight of complete transmitter 183 g (6.5 oz)