LT-WM DIN Rail Transmitter | Load Cell

MLT-P | 4-20 mA & Serial Data Output | Process & Ration Signals | DIN Rail Transmitter

The Micron Meters 4-20 mA and RS232/RS485 output, process signal input transmitter provides zero and span adjustment for use with a wide range of industrial transducers. Six DC voltage and four DC current input ranges are jumper selectable. The two most sensitive voltage ranges, 200.00 mV and 2.0000V, provide a high input impedance of 1 GΩ to minimize the load on the voltage signal.

The transmitter can be set to a ratio mode (or potentiometer follower mode) by making selections at the connector and in software. In this mode, the transmitter output tracks a ratio of the applied excitation voltage and is unaffected by changes in the excitation voltage. This capability is used for resistive bridge sensors and voltage dividers, such as potentiometers which track wiper position. Ratiometric measurements provide an exceptional accuracy of 0.01% of reading ± 2 counts.

Fast read rates at up to 50 or 60 conversions per second while integrating the signal over a full power line cycle are ideal for peak or valley capture and for real-time computer interface and control. Digital signal filtering modes are selectable for stable readings in electrically noisy environments. The internal digital readings and analog output can be individually selected to be either unfiltered or filtered.

Standard features of Micron LT transmitters include:

  • 4-20 mA, 0-10V or -10V to +10V analog transmitter output, isolated, jumper-selectable and user scalable. All selections provide 16-bit (0.0015%) resolution of output span and 0.02% output accuracy of a reading from -99,999 to +99,999 counts that is also transmitted digitally. Output isolation from signal and power grounds eliminates potential ground loop problems.
  • Serial communications output, RS232 or RS485 (half or full duplex), jumper selectable. Three protocols are user selectable: Modbus RTU, Modbus ASCII, or Custom ASCII. Modbus operation is fully compliant with Modbus Over Serial Line Specification V1.0 (2002). The Custom ASCII protocol is simpler than the Modbus protocol and is recommended when all devices are Micron units.
  • Dual solid state relays, isolated, for alarm or control. Rated 120 mA at 140 Vac or 180 Vdc.
  • Transducer excitation output, isolated. User selectable 5V@100 mA, 10V@120 mA or 24V@50 mA.
  • Universal 85-264 Vac power. Low-voltage 10-48 Vdc or 12-32 Vac power is optional.

Easy Transmitter programming is via the Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available. (P/N CBL04).

  MLT-P Process Transmitter | Support Library
  Data Sheet | User Manual

Select Transmitter Type
Select Main Board Option
Standard Main Board
Extended Main Board - Note: Extended allows custom curve linearization and rate from successive readings.
Select Power Option
Select Input Option Note: Load cells (4 or 6-wire, ratio-metric). Custom scaling. Specify min signal and displayed reading, max signal and displayed reading. 20-500 mV. Default excitation of 10V for up to four 350-ohm load cells in parallel.
Field scalable. Default scaling is 4-20 mA in = 4-20 mA out
Use P1 Note Field Below to enter Custom Scaling.
Specify min input, min output; max input, max output.
P1 Custom Scaling Note Field
Specify min input, min output; max input, max output.
Select Accessories
RS232 cable, 7ft. Connects RS232 screw terminals of LT transmitter to DB9 port of PC.
USB-to-DB9 adapter cable. Includes FTDI chip for compatibility with all versions of Windows. Combination of CBL02 and CBL04 connects PC USB port to LT RS232 port.
  • MLT | 4-20 mA & RS232/RS485 output transmitter
  • 2 ] Standard Main Board
  • 0 | Isolated 85-264 Vac or 90-300 Vdc
  • P Field scalable
  • P1 Custom Scaling Note Field