LT-FR DIN Rail Rate or Total, Pulse  Transmitter

MLT-FR | 4-20 mA & Serial Data Output | Pulse Input Totalizer | DIN Rail Transmitter

The Micron Meters pulse input totalizer transmitter accepts two independently scalable input channels from a wide range of pulse sources, such as NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC voltages to 250 Vac. Input pulse rates can be as high as 1 MHz.

With a Standard Main Board, the transmitter output can be scaled to track total (such as gallons) or rate (such as gallons per minute). Square root extrac­tion is standard.

With an Extended Main Board, the transmitter can also:

  • Count up to a preset or down from a preset to zero. Such applications typically utilize the transmitter's two solid state relays, which are standard. External reset of totals is via a special three-position screw terminal connector.
  • Perform custom-curve linearization on rate or total, for example to extend the range of transducers. Exceptionally accurate custom-curve linearization is provided by a curvilinear spline fit with up to 180 data points.
  • Combine channels A and B arithmetically so that the transmitter output tracks A+B (e.g., sum of two flows or totals), A-B (e.g., difference of two flows or totals), AxB (e.g., horse­power as product of force and RPM), A/B (ratio of two flow or totals), and A/B-1 (draw or relative elongation of material between rollers).
Signal conditioner board used with 4-20 mA current transmitter for frequency, rate or period

The dual-channel signal conditioner used for pulse detection accepts inputs from proximity switches with PNP or NPN output, TTL or CMOS logic, magnetic pickups, contact closures, and other signals from 12 mV to 250 Vac. Jumper selections provide optimum operation for different sensor types and noise conditions. A built-in 5V, 10V or 24V dc excitation supply can power proximity switches and other sensors, and eliminate the need for an external power supply.

Standard features of Micron MLTE transmitters include:

  • 4-20 mA, 0-20 mA, 0-10V or -10V to +10V analog transmitter output, isolated, jumper-selectable and user scalable. All selections provide 16-bit (0.0015%) resolution of output span and 0.02% output accuracy of a reading from -99,999 to +99,999 counts that is also transmitted digitally. Output isolation from signal and power grounds eliminates potential ground loops.
  • Serial communications output, RS232 or RS485 (half or full duplex), jumper selectable. Three protocols are user selectable: Modbus RTU, Modbus ASCII, or CustomASCII. Modbus operation is fully compliant with Modbus Over Serial Line Specification V1.0 (2002). The Custom ASCII protocol is simpler than the Modbus protocol and is recommended when all devices are Micron units.
  • Dual solid state relays, isolated, for alarm or control. Rated 120 mA at 140 Vac or 180 Vdc.
  • Transducer excitation output, isolated. User selectable 5V@100 mA, 10V@120 mA or 24V@50 mA.
  • Universal 85-264 Vac power. Low-voltage 10-48 Vdc or 12-32 Vac power is optional.

Easy Transmitter programming is via the Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available. (P/N CBL04).

  MLT-FR Pulse Input Totalizer Transmitter | Support Library
  Data Sheet | User Manual

Select Transmitter Type
Select Main Board Option Standard Main Board: Scalable to ±999,999 for frequency, rate, square root of rate, up or down total, period, A-to-B time interval. Extended Main Board: Above, plus rate and total simultaneously, ratio (A/B), draw (A/B-1), other arithmetic functions (AxB, A+B, A-B), phase angle, stopwatch, up/down counting, batching operation, linearization of nonlinear inputs.
Standard Main Board: Scalable to ±999,999 for frequency, rate, square root of rate, up or down total, period, A-to-B time interval.
Extended Main Board: Above, plus rate and total simultaneously, ratio (A/B), draw (A/B-1), other arithmetic functions (AxB, A+B, A-B), phase angle, stopwatch, up/down counting, batching operation, linearization of nonlinear inputs.
Select Power Option
Select Input Option
Select Accessories
Extended operating temperature option from -40°C to 70°C
RS232 cable, 7ft. Connects RS232 screw terminals of LT transmitter to DB9 port of PC.
USB-to-DB9 adapter cable. Includes FTDI chip for compatibility with all versions of Windows. Combination of CBL02 and CBL04 connects PC USB port to LT RS232 port.
  • MLT | 4-20 mA & RS232/RS485 output transmitter
  • 6 ] Standard Main Board
  • 0 | Isolated 85-264 Vac or 90-300 Vdc
  • FR Dual-Channel Pulse Input Signal Conditioner.