Our TR-5i Series data loggers are designed to measure and record temperature, voltage, 4-20mA, or pulse count. The body of the data loggers are water resistant and can be used in an environment of -40°C to 80°C. Moreover, battery-powered operation means the loggers can be placed anywhere without the need for AC power.
The data recorded by the loggers can be transferred to PC via separately sold "Communication Port TR-50U2" or "Data Collector TR-57DCi", whereby users can analyze the data and view in graph form.
Furthermore, our Data Collector TR-57DCi enables on-site data collection and viewing of data; no longer is it necessary to manually gather the data loggers.

EN 12830 Compliant
The TR-51i and TR-52i data loggers comply with EN12830, the European Standard regarding Temperature recorders for the transport, storage and distribution of chilled, frozen, deep-frozen/quick-frozen food and ice cream.
Micron Meters is an Authorized Distributor and Technical Partner for T&D Data Loggers.
Guided Navigation Tip:
Using the Drop-down menus located on the left, filter your current results based on your application requirements.

TandD (T&D)

T&D offers a variety of Wireless, Waterproof, Network capable Data Loggers for use in a wide range of applications. T&D Loggers measure, monitor and record Temperature, Humidity, Voltage, Current, 4-20mA, Pulses (counts), Co2 Carbon Dioxide, UV Intensity, Illuminance and Barometric Pressure.

Guided Navigation Tip:
The T&D product lineup is listed below with brief descriptions, for further detailed information click on any of the images or links below.

Series Overview

RTR-500 Series
Wireless Communication Logging System - a comprehensive suite of Data Collectors and Data Loggers that cover a wide range of applications.
Monitor and Record Temperature, Humidity, Voltages, Current 4~20mA, Pulses, UV and CO2.
Easy end-user setup allows for measurement thresholds to be defined and when a threshold is met the system will Alarm and send out warning messages via email and text.

TR-7wf/nw Series
This next generation of  Temperature and Humidity Data Recorders are LAN based which allows access to your data via the Cloud or by direct communication with mobile devices (wf series only). The loggers will auto-upload to your FREE and Secure Web-Storage account which allows you access anywhere, anytime to all your loggers and data.

TR4 Bluetooth Series
TR4 Bluetooth Series
The TR4 series are data loggers equipped with Bluetooth low energy. With a smartphone/tablet and our dedicated apps, logger communication and data management have never been easier. We offer dedicated apps for real-time monitoring of changing data and uploading recorded data to our free cloud service "T&D WebStorage Service".
 
  TR-5i Series
The TR-5i Series includes easy-to-use waterproof compact durable loggers for measuring temperature, voltage, 4-20mA, and pulse count and their low energy consumption design means longer battery life.
Collecting data is made easy with an IR enabled handheld collector for on site use or a portable USB connectable port for use with a PC.

  TR-7Ui Series
TR-7Ui Series includes USB/IR communication capable loggers for measuring not only temperature and humidity but other important environmental factors such as CO2, UV and Barometric Pressure.

MCR Series
Our MCR Series is made up of two types of 4-channel loggers
MCR-4V for voltage
MCR-4TC for wide range thermocouple sensors.
They can be mixed and combined for up to 16 channels of simultaneous recording.

RTR-601 Series
The RTR-601 makes food safety a snap and with the RTR-500NW/AW Base Station, data can be auto-uploaded for viewing from PC or mobile device.
 
VR-71
The VR-71 measures and records voltage signals within a range of DC(+/-)15V and can record common signals, such as 1-5V/4-20mA, as well as, output signals from a variety of sensors.

RTR-322 Log-EZ
The RTR-322 log-EZ logger is our most user friendly wireless model perfect for tracking temperature and humidity in a home or office from one PC with the USB dongle connected to it.
 
View All T&D Models

FAQ's
Here are some of the most Frequently Asked Questions about T&D Products.
If you don't find an answer to your question, send us an email.

Top 5 Questions

Yes, the battery life changes with various factors such as the measuring environment, frequency of communication, recording interval, and quality of the battery being used.
Your batteries may run out faster than stated in the spec or manual depending on the actual operating environment and conditions of use.
Please regard the estimated battery life as a reference.
Related Products All Series
Last Update November 30, 2016
For wireless data loggers, battery life is calculated based on the assumption that recorded data is downloaded via wireless communication once a day.
Monitoring current readings, for example, that requires frequent wireless data transmission, will shorten the battery life.
For non-wireless data loggers, the basic assumption used is a 10-sec (or longer) recording interval and transmission frequency of 4 times a month.
Related Products All Series
Last Update November 30, 2016
Indoor partition walls, ceilings, metal, and other obstacles can shorten the radio transmission range compared to an environment where radio waves can travel in a straight line from the Remote Unit to the Base Unit without any obstacles.
Radio waves also pass through and around obstacles leaking from gaps or spaces. Hence the transmission range depends on the building construction and contents of the rooms. Therefore, it is difficult to say what the transmission range will be when using in an indoor environment.
Related Products RTR-50, RTR-500 Series, RTR-51A/52A/53A, RTR-52Pt, RVR-52, RTR-57C, RTR-57U, RTR-5W, RTR-7 Series
Last Update November 30, 2016
The fluororesin part of the fluoropolymer coated sensor and the stainless protection tube of the stainless protection sensor are submersible and can be used in water applications. Other sensors cannot be submerged in water.
Related Products RTR-500 Series, RTR-51A/52A/53A, RTR-52Pt, RVR-52, RTR-71/72, RVR-71, RPR-72, TR-51/51A/52, TR-51S/52S, TR-5i Series, TR-700W Series, TR-71S/72S, TR-71U/72U, TR-71Ui/72Ui, TR-71W/72W, TR-81
Last Update November 30, 2016
An adjustment function for temperature measurements is available in the following models. (As of March 2016)
・TR-51S/52S
・TR-51i/52i/55i
・RTR-51A/52A/53A/52Pt
・RTR-501/502/503/505/507/574/576
・TR-71U/72U
・TR-71Ui/72Ui
・TR-71wf/72wf
・TR-71nw/72nw
・TR-73U
・TR-74Ui
・TR-76Ui
・TR-77Ui
・TR-71W/72W
・TR-701AW/702AW
・TR-701NW/702NW
・RTR-61
There is no adjustment function available for any models other than stated above.

FAQ'S by Category

Networks

What does the term "client" refer to?
In a network there is a server which stores, processes and distributes information; on the other hand there is a "client" which refers to a device which connects to the server to access information.
Related Products RTR-500NW/AW, RTR-5W, TR-700W Series, TR-71W/72W, TR-7wf/nw Series, WDR-3, WS-2
Last Update September 08, 2016
I want to have a mail sent when a warning occurs, how can I do this?
To use the warning mail function, it is necessary to have access to a SMTP/POP server. If you have an Internet connection, use the mail server of your Internet service provider or some other means to access a mail server. If you have a mail server on your company LAN, there may be specific instructions and settings for sending mail. Please ask the network administrator at your company for details. When using a TR-7wf/nw device with T&D WebStorage Service, it is not necessary to make SMTP server settings to send warning report mail from the WebStorage Server.
Related Products RTR-500 Series, TR-700W Series, TR-71W/72W, TR-7wf/nw Series, WDR-3, WS-2, RTR-50, RTR-5W
Last Update September 08, 2016

What is "POP3before"?
POP3before is one method used for the sending and receiving of mail. A mail server uses two types of protocol to send and receive mail. Generally when mail is sent it uses an SMTP server and when receiving mail uses a POP server. Normally, the sending and receiving of mail are done separately. However, recently in an effort to fight Spam mail a new type of mail server, referred to as POP3before, has been developed. The way it works is that after logging in with your Login ID and password to the POP server you can then have access to the SMTP server for a certain length of time in order to send mail.
Related Products RTR-500 Series, TR-700W Series, TR-71W/72W, WDR-3, WS-2
Last Update September 08, 2016

Is it possible to deactivate "POP3before"?
POP3before is controlled by the administrator of your company LAN or by your provider and unfortunately there is nothing that you can do to cancel it. If you wish to use the warning mail function, please make sure to use a mail server that complies with normal SMTP / POP specifications.
Related Products RTR-500 Series, TR-700W Series, TR-71W/72W, WDR-3, WS-2, RTR-50, RTR-5W
Last Update September 08, 2016

Data Loggers

How can I clear the data that is logged in a data logger?
In almost all of our data loggers there is no feature allowing you to clear data in and by itself.
By stopping and restarting recording, all data will automatically be cleared. In the MCR-4V and MCR-4TC it is possible to delete all recorded data from both the unit itself and via PC software.
Related Products All Series
Last Update September 02, 2016
Can the device be used in an environment exposed to ammonia gas?
Use in such an environment should be avoided; the exposure to gas will cause corrosion.
Related Products All Series
Last Update September 02, 2016

Can the device be used in a vacuum?
No, it cannot be used in a vacuum.
Related Products All Series
Last Update September 02, 2016

For how long is it possible to continuously record?
T&D data loggers basically come in two model types. Some models can record up to 8000 readings before becoming full and other models can record up to 16.000 readings before becoming full.

The amount of time that a logger can continuously record will be determined by the number of readings it can record and also by the recording interval at which it is set to record.
Below is a chart showing the longest amount of time each of the types of loggers can record before becoming full.
Please use this data as an estimate when deciding which type of logger to purchase.

For Devices with 8000 Readings

Recording Interval Longest Recording Time
  By seconds By minutes By hours By days By months
1s 8000s 133m20s 2h13m20s    
2s 16000s 266m40s 4h26m40s    
5s 40000s 666m40s 11h6m40s    
10s 80000s 1333m20s 22h13m20s    
15s 120000s 2000m 33h20m 1D6h20m  
20s 160000s 2666m40s 44h26m40s 1D20h26m40s  
30s 240000s 4000m 66h40m 2D12h40m  
1m   8000m 133h20m 5D13h20m  
2m   16000m 266h40m 11D2h40m  
5m   40000m 666h40m 27D18h40m  
10m   80000m 1333h20m 55D13h20m 1M25D13h20m
15m   120000m 2000h 83D8h 2M23D8h
20m   160000m 2666h40m 111D2h40m 3M21D2h40m
30m   240000m 4000h 166D16h 5M16D16h
1h     8000h 333D8h 11M3D8h

For Devices with 16000 Readings

Recording Interval Longest Recording Time
  By seconds By minutes By hours By days By months By years
1s 16000s 266m40s 4h26m40s      
2s 40000s 666m40s 11h6m40s      
5s 80000s 1333m20s 22h13m20s      
10s 120000s 2000m 33h20m 1D6h20m    
15s 160000s 2666m40s 44h26m40s 1D20h26m40s    
20s 240000s 4000m 66h40m 2D12h40m    
30s   8000m 133h20m 5D13h20m    
1m   16000m 266h40m 11D2h40m    
2m   40000m 666h40m 27D18h40m    
5m   80000m 1333h20m 55D13h20m 1M25D13h20m  
10m   120000m 2000h 83D8h 2M23D8h  
15m   160000m 2666h40m 111D2h40m 3M21D2h40m  
20m   240000m 4000h 166D16h 5M16D16h  
30m     8000h 333D8h 11M3D8h  
1h     16000h 666D16h 22M6D16h 1Y10M1D16h

About Units

Unit Explanation
Y Years
M Months
D Days
h Hours
m Minutes
s Seconds

* 1 month = 30 days


Related Products All Series
Last Update September 02, 2016

Can units with a waterproof rating of IP64 be used while submersed in water?
IP64 is a rating for everyday use; meaning it is splash resistant. Therefore splashes of water from a sink or rain will not be a problem, but it cannot be guaranteed for use while submersed in water.
The unit itself can be submersed in cold or hot water for a short time without water entering the unit. But if for example it was in hot water of 60℃ and then moved to cold water of 0℃, the internal pressure of the logger would drop and water may seep into the case.
If you wish to measure and record the temperature in water, please place only the sensor in the water.
Related Products RTR-502/502L, TR-52, TR-52S, TR-52i
Last Update September 02, 2016

Is battery life affected by the operating environment? Yes, the battery life changes with various factors such as the measuring environment, frequency of communication, recording interval, and quality of the battery being used. Your batteries may run out faster than stated in the spec or manual depending on the actual operating environment and conditions of use. Please regard the estimated battery life as a reference.
Related Products All Series
Last Update September 02, 2016

How is battery life expectancy calculated?
For wireless data loggers, battery life is calculated based on the assumption that recorded data is downloaded via wireless communication once a day.
Monitoring current readings, for example, that requires frequent wireless data transmission, will shorten the battery life.
For non-wireless data loggers, the basic assumption used is a 10-sec (or longer) recording interval and transmission frequency of 4 times a month.
Related Products All Series
Last Update September 05, 2016
Does recording continue even while communicating with the PC?
Yes, recording in the data logger is not affected by communication with the PC. Measurement and recording will continue during communication.
Related Products All Series
Last Update September 06, 2016

I am using Windows 7, what can I do if the USB driver installations seems to have failed?
If the installation has failed first please check to make sure that the version of the software you used is compatible with Windows 7. If it was compatible but still the PC did not recognize the driver, please see the link below and try reinstalling the USB driver.
Reinstalling USB Driver on Windows 7
Related Products TR-7Ui Series, TR-7wf/nw Series, TR-50U2, TR-57DCi
Last Update November 21, 2016

Sensors

What kind of measurement precision loss can I expect after using for some time?
The circuitry in the device has been designed to withstand the effects of changes in the surrounding environment and changes in electrical properties; therefore the precision of the measurements does not degrade over time.
Although the sensor element of the temperature sensor does not experience loss of precision due to use over time, due to external factors, such as build up of water, losses in precision will occur. If you find that measurements are becoming less and less precise, we suggest changing the sensor. Humidity sensors will also lose precision due to water and dust buildup.
Related Products RTR-501/501L, RTR-502/502L, RTR-503/503L, RTR-505-Pt/505-PtL, RTR-505-TC/505-TCL, RTR-507/507L, RTR-51A/51AL, RTR-52A/52AL, RTR-52Pt/PtL, RTR-71/72, RVR-71, RPR-72, TR-51/51A/52, TR-51S/52S, TR-51i, TR-52i, TR-55i-Pt, TR-55i-TC, TR-700W Series, TR-71S/72S, TR-71U/72U, TR-71Ui/72Ui, TR-71W/72W, TR-73U, TR-7wf/nw Series, TR-81
Last Update September 02, 2016

What does Thermal Time Constant mean?
This is an estimate of response time based on JIS standards. It is the amount of time it takes for the 63.2% of the temperature measurement to be reached.
Related Products RTR-500 Series, RTR-51A/52A/53A, RTR-52Pt, RVR-52, RTR-601 Series, RTR-61, RTR-7 Series, TR-51/51A/52, TR-51S/52S, TR-5i Series, TR-700W Series, TR-71S/72S, TR-71U/72U, TR-71W/72W, TR-73U, TR-7Ui Series, TR-7wf/nw Series, TR-81
Last Update September 08, 2016

Is it possible to use some kind of sensor extension cable?
The maximum length and compatible extension cables vary depending upon which logger is being used.
See below for details.
【TR-71nw, TR-71wf, TR-701NW, TR-701AW, TR-71W, TR-71Ui, TR-71U, TR-71S】
Compatible Extension Cables: TR-1C30 (3m), TR-5C10 (1m)
Up to 3 meters of extension cables can be used per sensor.

【RTR-502, TR-52i, RTR-71, RTR-52/52A, TR-52S, TR-52】
Compatible Extension Cables: TR-2C30 (3m)
Up to 3 meters of extension cables can be used per sensor.

【RTR-505-Pt, TR-81, RTR-52Pt】
There are no separate extension cables for these loggers, but T&D order-made Pt100 sensors come in various types and lengths of up to 99 meters. If a long cable is necessary we strongly suggest using one of these logger models.
Note that Pt100 sensors are produced only upon receipt of order; therefore please allow four weeks from the time of order until shipping.

【TR-73U, TR-72W, TR-72Ui, TR-72U, TR-72S】
Temp-humidity sensor cables over 1 meter cannot be used for the above models.
The TR-3100 sensor supplied with TR-73U, TR-72Ui and TR-72U can use the extension cable TR-5C10 (1m). Note that the temp-humidity sensor TR-3110 with 1-meter cable cannot be extended. If you are using an optional temperature-only sensor, up to 3 meters of extension cables can be used per sensor.
Compatible Extension Cables: TR-1C30 (3m), TR-5C10 (1m)

【TR-72nw, TR-72wf, RTR-574, RTR-576, TR-74Ui, TR-76Ui, TR-702NW, TR-702AW, TR-77Ui】
Compatible Extension Cables: TR-1C30 (3m), TR-5C10 (1m)
Up to 9 meters of extension cables can be used per sensor.

【RTR-507, RTR-505, TR-55i】
Compatible Extension Cables: TR-3C30 (3m)
Up to 3 meters of extension cables can be used per sensor/module.

【RTR-503, RTR-72, RTR-53/53A】
Extension cables cannot be used with these models.

Related Products TR-700W Series, TR-7Ui Series, TR-7wf/nw Series, RTR-502/502L, RTR-503/503L, RTR-505-P/505-PL, RTR-505-Pt/505-PtL, RTR-505-TC/505-TCL, RTR-505-V/505-VL, RTR-505-mA/505-mAL, RTR-507/507L, RTR-574/574-H, RTR-576/576-H, RTR-52A/52AL, RTR-52Pt/PtL, RTR-53A, RTR-71, RTR-72, TR-52, TR-52S, TR-52i, TR-55i-P, TR-55i-Pt, TR-55i-TC, TR-55i-V, TR-55i-mA, TR-71S, TR-71U, TR-71W, TR-72W, TR-72S, TR-72U, TR-73U, TR-81
Last Update December 16, 2016
Is it OK to submerge the temperature sensor in water?
The fluororesin part of the fluoropolymer coated sensor and the stainless protection tube of the stainless protection sensor are submersible and can be used in water applications. Other sensors cannot be submerged in water.
Related Products RTR-500 Series, RTR-51A/52A/53A, RTR-52Pt, RVR-52, RTR-71/72, RVR-71, RPR-72, TR-51/51A/52, TR-51S/52S, TR-5i Series, TR-700W Series, TR-71S/72S, TR-71U/72U, TR-71Ui/72Ui, TR-71W/72W, TR-81
Last Update September 02, 2016

Which sensors are waterproof?
Basically, our waterproof sensor lineup can be broken down into three categories.
Please make a choice depending upon your individual needs.

1: Sensor tip (stainless protection tube) is waterproof but cable is not.
The following fall into this category: TR-0306, TR-0406, TR-0506, TR-0706.
These are optional sensors for TR-71wf/71nw, TR-73U, TR-71Ui/72Ui, TR-71U/72U, TR-701NW/701AW and TR-71W/72W.

2: Sensor tip (stainless protection tube) is waterproof and cable is rated for short term immersion (IPX7).
The following three kinds fall into this category:
a) TR-1220 and TR-1320
These are optional sensors for TR-71wf/71nw, TR-71Ui, TR-701NW/701AW, TR-71W and TR-71U.

b) TR-5220, TR-5320, and TR-5420
These are optional sensors for RTR-502, TR-52i, TR-52(S), RTR-52/52A and RTR-71.

c) TR-81XX
This is an optional sensor for RTR-505-Pt, TR-55i-Pt, TR-81 and RTR-52Pt. The Pt sensors can be ordered with tip (stainless protection tube) lengths from 50mm to 2000mm. (L-types included)

*Immersion proof (IPX7) means the object can be put into water of up to 1m in depth for 30 minutes without intrusion. Therefore the part which is rated for short term immersion can not be used continuously immersed in water.

3: From tip to cable connector is rated for continuous immersion (IPX8).
The following fall into this category: TR-5106 and TR-5530
These are optional sensors for RTR-502, TR-52i, TR-52(S), RTR-52 and RTR-71. (including L type)
Related Products TR-71W/72W, RTR-502/502L, RTR-505-Pt/505-PtL, RTR-52A/52AL, RTR-52/52L, RTR-52Pt/PtL, RTR-71, TR-52, TR-52S, TR-52i, TR-55i-Pt, TR-701AW, TR-701NW, TR-71U, TR-71Ui, TR-71nw, TR-71wf, TR-72U, TR-72Ui, TR-73U, TR-81
Last Update September 09, 2016

Is it possible to use sensors from other manufacturers?
It is possible only for platinum resistance sensors used with logger models RTR-502Pt, TR-55i-Pt, TR-81 and RTR-52Pt and thermocouple sensors used with MCR-4TC, RTR-505-TC and TR-55i-TC loggers.
For all other products it is necessary to use T&D designed thermistor sensors. Other manufacturer's thermistor sensors are not compatible with T&D products.
Related Products MCR-4TC, RTR-500 Series, RTR-51A/52A/53A, RTR-52Pt, RVR-52, RTR-7 Series, TR-5i Series, TR-700W Series, TR-71S/72S, TR-71U/72U, TR-73U, TR-7Ui Series, TR-7wf/nw Series, TR-81
Last Update September 02, 2016

Which part of the temperature sensor actually measures the temperature?
The sensor area is 3-5mm from the tip.This is common for all external temperature sensors.
Related Products RTR-500 Series, RTR-51A/52A/53A, RTR-52Pt, RVR-52, RTR-601 Series, RTR-61, RTR-71/72, RVR-71, RPR-72, TR-51/51A/52, TR-51S/52S, TR-5i Series, TR-700W Series, TR-71S/72S, TR-71U/72U, TR-71W/72W, TR-7Ui Series, TR-7wf/nw Series, TR-81
Last Update September 08, 2016
What are the small stickers attached to the temperature-humidity sensor?
Attached to our older model temp-humidity sensors (TR-3100/TR-3110/TR-3220) are two stickers: a wetness detection sticker and a temperature detection sticker.
Note that only one sticker (a temperature detection sticker) is attached to our newer model temp-humidity sensors (TR-3310/THA-3001/THA-3151/HHA-3151/HHB-3101).
If any of the stickers shows abnormality, you should replace the sensor immediately.


If it is pink it is normal.
If the sensor was used under high temperature conditions the sticker color will change as shown in the picture to the right.
Related Products RTR-503/503L, RTR-507/507L, RTR-574/574-H, RTR-576/576-H, RTR-53A, RTR-72, TR-702AW/702AW-H, TR-702NW/702NW-H, TR-72W, TR-72S, TR-72U, TR-72Ui, TR-72nw/72nw-H, TR-72wf/72wf-H, TR-73U, TR-74Ui/74Ui-H, TR-76Ui/76Ui-H, TR-77Ui
Last Update December 16, 2016

Wireless Communication

Will the wireless transmission range be shortened when the Remote and Base Units are used inside a building?
Indoor partition walls, ceilings, metal, and other obstacles can shorten the radio transmission range compared to an environment where radio waves can travel in a straight line from the Remote Unit to the Base Unit without any obstacles.
Radio waves also pass through and around obstacles leaking from gaps or spaces. Hence the transmission range depends on the building construction and contents of the rooms. Therefore, it is difficult to say what the transmission range will be when using in an indoor environment.
Related Products RTR-50, RTR-500 Series, RTR-51A/52A/53A, RTR-52Pt, RVR-52, RTR-57C, RTR-57U, RTR-5W, RTR-7 Series
Last Update September 02, 2016
Can the wireless communication between Base and Remote Units have an effect on other nearby devices?
The wireless radio frequency output during communication in the RTR-500 and RTR-7 Series are about 10mW; about the same as a low power transceiver.
Output for the RTR-5 Series is just one-tenth of that or 1mW. Hence no effect will occur on nearby devices or equipment.
Moreover, the devices are registered with the proper authority and comply with local regulations (FCC or CE); there should be no interference with communication of other nearby devices.
Related Products RTR-5 Series, RTR-50, RTR-500 Series, RTR-57C, RTR-57U, RTR-5W, RTR-7 Series
Last Update September 02, 2016

Do other nearby wireless devices and/or electronic devices which give off noise have an effect on the data logger wireless communication?
Yes, high output wireless devices or other electronic devices which put out high levels of noise in close proximity will have an effect on communication.
RTR-500, RTR-7 and RTR-5 Series are all designed with a retry function that will resend a communication that was not successfully completed.
Moreover, in the RTR-7 Series, if noise or other trouble is detected before communication is carried out, the base unit will automatically search out a unaffected frequency channel to carry out communication.
Note however that even with these features successful communication can not be guaranteed.
Related Products RTR-5 Series, RTR-50, RTR-500 Series, RTR-57C, RTR-57U, RTR-5W, RTR-7 Series
Last Update September 02, 2016

If I use two similar devices in close proximity will it cause communication interference?
If two or more wireless loggers from the same series are used in separate logging systems it may cause interference.
The RTR-500, RTR-7 and RTR-5 Series are all designed with a multiple number of frequency channels for communication between the Base and Remote Units. If interference occurs or you think it may occur, it is possible to change the frequency channels to alleviate that problem.
For the RTR-500 Series and the RTR-5 Series it is possible to make frequency channel settings when registering loggers as Remote Units to a Base Unit. In the RTR-7 Series, the Base Unit has a function to auto-search for unused channels whereby settings can be made
Related Products RTR-5 Series, RTR-50, RTR-500 Series, RTR-57C, RTR-57U, RTR-5W, RTR-7 Series
Last Update September 02, 2016

Measuring Temperature and Humidity

Why is the temperature measurement range narrower in the temperature-humidity sensors than in the temperature sensors?
Because the temperature durability range for the humidity sensor is lower and both the temperature and humidity sensors are inside one case, the possible measurement range becomes narrower.
Related Products TR-71S/72S, TR-71U/72U, TR-71Ui/72Ui, TR-71W/72W
Last Update September 02, 2016

Is there an adjustment function to correct temperature measurements?
An adjustment function for temperature measurements is available in the following models. (As of March 2016)
・TR-51S/52S
・TR-51i/52i/55i
・RTR-51A/52A/53A/52Pt
・RTR-501/502/503/505/507/574/576
・TR-71U/72U
・TR-71Ui/72Ui
・TR-71wf/72wf
・TR-71nw/72nw
・TR-73U
・TR-74Ui
・TR-76Ui
・TR-77Ui
・TR-71W/72W
・TR-701AW/702AW
・TR-701NW/702NW
・RTR-61
There is no adjustment function available for any models other than stated above.
Related Products RTR-500 Series, RTR-51A/52A/53A, RTR-52Pt, RVR-52, RTR-61, TR-51S/52S, TR-5i Series, TR-700W Series, TR-71U/72U, TR-71W/72W, TR-7Ui Series, TR-7wf/nw Series
Last Update September 02, 2016

What happens if a measurement goes beyond the specified measurement range of the logger?
Even if a measurement goes above or below the range noted in the specifications it will appear on the display and will be recorded, but the measurement is not guaranteed to be accurate above or below the stated range.
Related Products RTR-322, RTR-500 Series, RTR-601 Series, RTR-61, RTR-71/72, RVR-71, RPR-72, TR-51/51A/52, TR-51S/52S, TR-5i Series, TR-700W Series, TR-71S/72S, TR-71U/72U, TR-71W/72W, TR-7Ui Series, TR-7wf/nw Series, TR-81, MCR-4TC, TR-73U
Last Update September 08, 2016

Are any of your models compatible with thermocouple sensors?
Yes, thermocouple sensors can be used with the following loggers: MCR-4TC, RTR-505-TC, TR-55i-TC and TR-75nw/wf series.
Thermocouple sensors are not included with the loggers , so please purchase speak with our customer service dept about purchasing sensors.
Related Products MCR-4TC, RTR-505-TC/505-TCL, TR-55i-TC ,TR-75wf/nw
Last Update September 07, 2017
What is Hysteresis?
In general it stands for a condition in which there is a lag in response exhibited when reacting to changes in external forces so that although the conditions have been met for the affected body to return to its original state it does not for some time. Capacitance type humidity sensors (SHA-3151, SHB-3101) used in our High Precision Wide Range Temperature and Humidity Data Loggers will exhibit hysteresis upon returning to normal from very high humidity. Differences of ±1.5%RH may occur.
Moreover, when used in high temperature and high humidity environments (50℃/75%, 60℃/50%, 70℃/35%, and 80℃/25%) sensor hysteresis may become even larger and exceed ±1.5%RH.
Note that under certain circumstances, it may take several days to return to normal.
Related Products RTR-500 Series, TR-700W Series, TR-7Ui Series, TR-7wf/nw Series
Last Update September 02, 2016

Software

Is it possible to monitor real-time graphs on PC?
For the following devices it is possible to use T&D's cloud service and/or software to automatically upload/collect current readings at a set interval and then view in graph form. Shortest possible intervals and methods for auto data upload/collection vary depending on the device, therefore please check the user's manual or HELP in the software for details.
Related Products RTR-50, RTR-500, RTR-500MBS-A, RTR-500NW/AW, TR-701AW, TR-701NW, TR-702AW/702AW-H, TR-702NW/702NW-H, TR-71U, TR-71Ui, TR-71nw, TR-71wf, TR-72U, TR-72Ui, TR-72nw/72nw-H, TR-72wf/72wf-H, TR-73U, TR-77Ui, VR-71, RTR-322 Wireless Dongle Set/322
Last Update October 05, 2016
When exporting graph as text data (in CSV format), I see the column "@date()". What does it mean?
In Excel dates are shown as serial values.
(*The Excel serial value 1 corresponds to January 1, 1900.)
Excel stores dates as sequential serial numbers so that they can be used in calculations.
In order to change the date format, right click on the selected date column and choose "Format Cells", then select Date under Category and the desired type. Related Products All Series
Last Update September 02, 2016

Is it possible to process downloaded data with Excel and other spreadsheet software?
The downloaded data can be saved in CSV text format, which enables common spreadsheet software such as Excel to edit the data for graphic display.

Please see below for how to use Excel.

【When using Temperature/Humidity Graph】
  1. Open the graph you wish to convert to Excel data.
  2. In Temperature/Humidity Graph, from the [File] menu, select [Save Data in Text File]. In the Text File Settings dialog box, set the Delimiter to "Tab", select the range to be saved, and then click [OK].
  3. In the File Type dropdown list, select [All Files], enter the file name with an Excel extension, and click [Save].
    (Ex) Test.xls
※If file extensions are not shown, see below.
  1. In the Windows Control Panel, open [Folder Options].
  2. Click the View tab, and under Advanced Settings remove the check from next to the "Hide file extensions for known file types" option. Click [OK].

【When using T&D Graph】
  1. Open the graph you wish to convert to Excel data.
  2. In T&D Graph, from the [File] menu, select [Save in CSV Format].
  3. In the File Type drop down list select [comma delimited], enter the file name, and click [Save].
    (Ex) Test.csv
Now you can open the saved file in Excel.
Related Products All Series
Last Update September 02, 2016

Is it possible to modify or make changes to the downloaded data?
It is possible to make changes to the Recording Start Date and Time, but you cannot modify the recorded data.
Related Products All Series
Last Update September 08, 2016
Is there software available for Mac OS?
No, we do not have any software available for use with MAC OS or OS X.
Related Products All Series
Last Update September 08, 2016
How can I get the communication specifications for your software?
Please contact Micron Meters.
Related Products All Series
Last Update September 08, 2016

Do you accept requests for customizations of the software?
Sorry, but we do not customize our software.
Communication specifications and DLL for some of our products are available for you to help you in creating your own software programs.
Please contact Micron Meters if you're interested.
Related Products All Series
Last Update September 08, 2016

Calibration Options

Calibration certificates can be purchased along with the logger at the point of sale. Tinytags already in use can also be returned for a service calibration at any time, for a standard charge.

Tinytag data loggers are guaranteed to meet the specification stated on their data sheets for a twelve month period from the point of purchase. If required, additional validation certificates traceable to national standards may be purchased when buying the loggers. These calibration certificates can be provided at the time of purchase. Tinytags already in use can also be returned for a service calibration at any time, for a standard charge.

Calibration Certificates

The calibration certificate provides verification that the data logger has been checked and has been found to be reading within the specification quoted on the unit's data sheet. Data loggers are compared to a reference meter that has been calibrated in a UKAS (United Kingdom Accreditation Service) approved laboratory. The certificate lists the value recorded by the reference meter (the point at which the data logger was tested), the value recorded by the data logger and the error between the two readings (the certificate will also show readings before and after any adjustment made to the unit where appropriate). In addition to the reading information, calibration certificates also list the test method and the details of the equipment used to provide traceability back to national standards.

Calibration certificates do not have a period of validity, they are simply a statement of what the unit was reading when it was tested.

Standard Calibration Points

For temperature and humidity loggers, our standard calibration points, which are used unless otherwise specified, are:

  • Temperature: 0 and 30°C
  • Humidity: 20 and 80 % RH (at 25°C)
These points have been chosen to give good coverage for general purpose use, but should other points be required we can calibrate units within the following ranges:

  • Temperature: -20 to +150 °C
  • Humidity: 20 to 90 % RH (at 25°C)
CO2 loggers, our calibration points are:

  • 0 to 2000ppm units: 250, 500 and 1750ppm
  • 0 to 5000ppm units: 500, 2,500 and 4000ppm

We do not have standard calibration points for voltage and current loggers. Please contact us to discuss the calibration points you require.
Sort By:
Items per page:
TR-51i Internal Sensor Temperature Logger
Regular Price: $129.00
Micron's Web Price: $126.00
TR-52i | External Sensor Temperature Logger
Regular Price: $149.00
Micron's Web Price: $145.00
TR-55i-PT | PT100 and PT1000 Sensor Temperature Logger
Regular Price: $199.00
Micron's Web Price: $194.00
TR-55i-TC | Thermocouple K,J,T,S  Type Sensor Temperature Logger
Regular Price: $219.00
Micron's Web Price: $213.00
TR-55i-V | Voltage (0-22V) with Preheat Function
Regular Price: $199.00
Micron's Web Price: $194.00
TR-55i-mA | 4-20mA (operational to 40mA)
Regular Price: $199.00
Micron's Web Price: $194.00
TR-55i-P | Pulse Sensor
Regular Price: $149.00
Micron's Web Price: $145.00
TR-50U2 Communication Port | TR-5i Series Data Collector
Regular Price: $189.00
Micron's Web Price: $184.00
Sort By:
Items per page:
Loading...