TV-4505| Logger with display and temp/RH probe

TV-4506 | External Probe Sensors | Temperature -25 to +85°C (-13°F to +185°F) | Humidity 0 to 100%

The TV-4506 monitors Temperatures from -25 to +85°C (-13°F to +185°F) and Relative Humidity from 0 to 100% using an accompanying temperature and RH probe with a 1.5 meter cable. The coated RH sensor offers good resistance to moisture and condensation. Like the rest of the View 2 range, this accurate and reliable unit has a display.
Requires:Tinytag Explorer software,  USB cable.
Tech. Tip: Hover and Click on any of the icons below.

Adobe PDF Documents Tinytag TV-4506  | Support Library
| Data Sheet-TV-4506 |

This product qualifies for quantity discount pricing.(what's this?)
The TV-4506 monitors Temperatures from -25 to +85°C (-13°F to +185°F) and Relative Humidity from 0 to 100% using an accompanying temperature and RH probe with a 1.5 meter cable. The coated RH sensor offers good resistance to moisture and condensation.
Tinytag View 2 | TV-4506 | Temperature & RH data logger with probe
Tinytag Explorer is the Windows program used to configure Tinytag loggers and view recorded data. During set up, logger names, logging intervals and alarm settings can easily be chosen. Recorded data can be shown as a graph, table of readings or summary information.
Interface cables are used for connecting the logger to a PC for programming and recovering stored data.
Listed Below are several options for purchasing the required software and interface cable for the TGU-4020 Logger. The most economical package is the (SWPK7-USB) it includes both the Explorer Software (SWCD-0040) and the Interface Cable (CAB-0007-USB).
Select No Thanks if you already have the Software and Interface cable.
Purchase this if you already have an Interface Cable.
Purchase this if you already have a copy of the Software.
Purchase this if you need both the Software and an Interface Cable.

Understanding Calibration

During calibration data loggers are compared to a reference meter that has been calibrated in a UKAS (United Kingdom Accreditation Service) approved laboratory. Data Loggers for use with a probe are calibrated with the accompanying probe. The certificate lists the value recorded by the reference meter (the temperature or humidity at which the data logger was tested), the value recorded by the data logger and the error between the two readings (the certificate will also show readings before and after any adjustment made to the unit where appropriate). In addition to the reading information, calibration certificates also list the test method and the details of the equipment used to provide traceability back to national standards.

Calibration certificates do not have a period of validity; they are simply a statement of what the unit was reading when it was tested. That said, unless the application is particularly critical or demanding, most people get their loggers calibrated annually.

Even if you don't purchase calibration certificates, we guarantee that our loggers will meet the accuracy figures specified on our datasheets at the point of purchase.

Calibration Points

Our standard calibration points, which are used unless otherwise specified, are:
• Temperature: 0 and 30°C
• Humidity: 20 and 80 % RH (at 25°C)

These points have been chosen to give good coverage for general purpose use, but should other points be required we can calibrate units within the following ranges:
• Temperature: -20 to +150 °C
• Humidity: 20 to 90 % RH (at 25°C)

U.K.A.S. (N.I.S.T.) Traceable Certificate of Calibration.
Customer Specified Calibration (1 additional Point. Use Text Field. Below to Enter your Point
Customer Specified Calibration (2) additonal Points. Use Text Field. Below to Enter your Point

Calibration Points

Our standard calibration points, which are used unless otherwise specified, are:
• Temperature: 0 and 30°C
• Humidity: 20 and 80 % RH (at 25°C)

These points have been chosen to give good coverage for general purpose use, but should other points be required we can calibrate units within the following ranges:
• Temperature: -20 to +150 °C
• Humidity: 20 to 90 % RH (at 25°C)

Enter Data into this field if you selected a Calibration with Extra Point(s).
Cal. Points
Enter your Extra Calibration Point Here, Designate Degrees C or F
Enter a value between -20°c to +150°c (-4°F to 302°F)
Example: 12 degrees F
  • TV-4506
  • Software+Cable (No Thanks)
  • Calibration Certificate (No Thanks)
$344.35
$344.35
View More Info.- Click NowRequired Items and Optional Accessories...
Loading...