LTE-TC DIN Rail Transmitter | Thermocouple

MLTE-TC | Ethernet & 4-20 mA Output | Thermocouple | DIN Rail Transmitter

The Micron Thermocouple transmitter provides a linearized, highly accurate, stable and repeatable transmitter output for Thermocouple types J, K, T, E, N, R or S. The thermocouple type and temperature range, specified in °C or °F, are user-selectable. The temperature range can be as wide as the entire span of the thermocouple type, or as narrow as 150 counts (such as 15.0°), limited only by considerations of electrical noise and digital filtering time constants.

Thermocouple signal conditioner board

Digital calibration of all thermocouple ranges is performed the factory, with calibration data stored in EEPROM on the signal conditioner board. This allows signal conditioner boards and ranges to be changed in the field with no need for re calibration. Cold junction compensation automatically corrects for temperature variations at the thermocouple reference junction at the transmitter. Open sensor indication is standard and may be set up to indicate either upscale or downscale.

Fast read rate at up to 50 or 60 conversions per second while integrating the signal over a full power line cycle is ideal for peak or valley capture and for real-time computer interface and control.

Standard features of Micron MLTE transmitters include:

  • Ethernet I/O, isolated. Supported protocols are Modbus RTU and ASCII (tunneled via Modbus TCP) and Custom ASCII. The latter is simpler than the Modbus protocol and is recommended when all devices are Micron units. Note that RS232 or RS485 data I/O in lieu of Ethernet is provided by LT Series transmitters.
  • 4-20 mA, 0-20 mA or 0-10V analog transmitter output, isolated, jumper-selectable and user scalable. All selections provide 16-bit (0.0015%) resolution of output span and 0.02% output accuracy of a reading from -99,999 to +99,999 counts that is also transmitted digitally. Output isolation from signal and power grounds eliminates potential ground loop problems. The supply can drive 20 mA into a 500 ohm (or lower) load for 10V compliance, or 10V into a 5K ohm (or higher) load for 2 mA compliance.
  • Dual solid state relays, isolated. Available for local alarm or control. Rated 120 mA at 130 Vac or 180 Vdc.
  • Universal 85-264 Vac power. Low-voltage 10-48 Vdc or 12-32 Vac power is optional.

Discovery and configuration of the Ethernet Nodes is easily achieved with the Node Manager Software, and the discovered transmitters can then be programmed using the  Instrument Setup Software. Both software's run on a PC under MS Windows and can be downloaded from this website at no charge.

Ethernet network

  MLTE-TC Thermocouple Transmitter | Support Library
  Data Sheet | User Manual
Select Transmitter Type
Select Main Board Option
Standard Main Board
Select Power Option
Select Input Option Note: The same signal conditioner board can be user configured for all thermocouple types listed and °C or °F.
  • MLTE | Ethernet & 4-20 mA output transmitter
  • 2 ] Standard Main Board
  • 0 | Isolated 85-264 Vac or 90-300 Vdc
  • JC Thermocouple Type J, -210°C to 760°C