LT-FR  4-20 mA & RS485 Transmitter for Stopwatch Timing for Single Events DIN Rail Transmitter

MLT-FR | 4-20 mA & Serial Data Output | Stopwatch Timing for Single Events | DIN Rail Transmitter

accumulated time

The Micron Meters stopwatch transmitter puts out isolated analog and serial data output signals whose values track the time of single events which produce start and stop pulses, or the accu­mulated time of multiple events. It can also time the width of a single pulse. The highest resolution is 0.2 µs, making the transmitter ideal for fast events. The longest timing interval is 999,999 hrs. For long events, the analog output is updated continuously during timing. There are two primary timing modes:

  • A-A Stopwatch Mode. Time is measured between a start pulse and a stop pulse, both on Channel A, from either the positive or negative edges.
  • A-B Stopwatch Mode. Time is measured between a start pulse on Channel A (positive or negative edge) and a stop pulse on Channel B (positive or negative edge). This mode allows inputs from different sources. In addition, the A and B inputs can be tied together to start the stopwatch with one polarity and stop it with the other polarity.

Event time (Item #1) is measured by counting 5.5 MHz clock pulses from a calibrated quartz crystal. The stopwatch output is updated during timing at a rate controlled by a gate time, up to 25/sec. Time is reset to zero when the next start pulse occurs. Accumulated time from multiple events up to 999,999 hours (Item #2) is also tracked.

Signal Conditioner Board for Micron Digital Time Interval Transmitter and Digital Timer

The dual-channel signal conditioner used for pulse detection accepts inputs from proximity switches with PNP or NPN output, TTL or CMOS logic, magnetic pickups, contact closures, and other signals from 12 mV to 250 Vac. Jumper selections provide optimum operation for different sensor types and noise conditions. A built-in 5V, 10V or 24V dc excitation supply can power proximity switches and other sensors, and eliminate the need for an external power supply.

  Standard features of Micron MLT transmitters include:
  • 4-20 mA, 0-10V or -10V to +10V analog transmitter output, isolated, jumper-selectable and user scalable. All selections provide 16-bit (0.0015%) resolution of output span and 0.02% output accuracy of a reading from -99,999 to +99,999 counts that is also transmitted digitally. Output isolation from signal and power grounds eliminates potential ground loop problems.
  • Serial communications output, RS232 or RS485 (half or full duplex), jumper selectable. Three protocols are user selectable: Modbus RTU, Modbus ASCII, or Custom ASCII. Modbus operation is fully compliant with Modbus Over Serial Line Specification V1.0 (2002). The Custom ASCII protocol is simpler than the Modbus protocol and is recommended when all devices are Micron units.
  • Dual solid state relays, isolated, for alarm or control. Rated 120 mA at 130 Vac or 170 Vdc.
  • Transducer excitation output, isolated. User selectable 5V@100 mA, 10V@120 mA or 24V@50 mA.
  • Universal 85-264 Vac power. Low-voltage 10-48 Vdc or 12-32 Vac power is optional.

Easy Transmitter programming is via the Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available. (P/N CBL04).

  MLT-FR  Stopwatch Timer Transmitter | Support Library
  Data Sheet | User Manual

Select Transmitter Type
Select Main Board Option
Select Power Option
Select Input Option
Select Accessories
RS232 cable, 7ft. Connects RS232 screw terminals of LT transmitter to DB9 port of PC.
USB-to-DB9 adapter cable. Includes FTDI chip for compatibility with all versions of Windows. Combination of CBL02 and CBL04 connects PC USB port to LT RS232 port.
  • MLT | 4-20 mA & RS232/RS485 output transmitter
  • 6 | Standard Main Board
  • 0 | Isolated 85-264 Vac or 90-300 Vdc
  • FR Dual-Channel Pulse Input