ICA H & S

ICA H | ICA S | Miniature Strain Gauge Amplifier, Converts Load Cell to 4-20mA & 0-10V

  • Fits inside sensors, 19.5 mm diameter, 7.6 mm height
  • Outputs of 4-20 mA, 0-10 V, 0-5 V, ±10 V
  • Non interaction between the trimmers makes calibration fast and easy
  • High speed 1000 Hz
  • Robust design, of high noise immunity & reverse polarity protected
  • 2 wire 4-20 mA load cell option

ICA Range

The ICA range of miniature strain gauge amplifier offer a high performance strain gauge amplifier in miniature OEM format, designed specifically for fitting inside load cells, converts load cell to 4-20 mA & 0-10 V output.

The ICA family offers high stability and fast response.

The miniature strain gauge amplifier is available in 6 versions, ICA1H, 2H, 3H, 4H & 6H with high performance and ICA5S with industrial stability.

The ICAH range offer very low drift over wide operating temperatures.

Optional (ILE) in line enclosure to convert a standard load cell to a conditioned load cell output

Very High Stability ICAH
  • ICA1H 0-10 V 3 wire
  • ICA2H 0-5 V 3 wire
  • ICA3H ± 10 V 4 wire
  • ICA4H 4-20 mA 3 wire
  • ICA6H ± 10 V 3 wire
Industrial Stability ICAS
  • ICA5S 4-20 mA 2 wire
ATEX Intrinsically Safe
  • ICA5ATEX 4-20 mA 2 wire

ICA1,2,3,6H Voltage Output Amplifiers

ICA1H 0.1-10.1 V

Parameter Min Typical Max Units/Notes
Electrical & Environmental
Supply Voltage Range 13  24  28  Volts
Operating Current   22   mA Note 1
Operating Temp Range -40    85  ºC
Storage Temp Range -40    85  ºC
Reverse Polarity Protection -30     Volts
Measurements
Bridge Excitation 4.9  5.1  Volts
Bridge Impedance 350 1000 5000  Ohms
Bridge Sensitivity 0.5  2.5  150  mV/V Note 2
Output Voltage Range 0.1   +10.1  Volts
Output Load 5000      Ohms
Band Width DC    1000  Hz
Zero Adjustment   ±2   %FR
Span Adjustment   ±8   %FR
Linearity   0.02    %FR
Zero Temp Stability H   0.0004  0.0015  ±%FR/ºC
Span Temp Stability H   0.002  0.0051  ±%FR/ºC

ICA2H 0.1-5.1 V

Electrical & Environmental
Supply Voltage Range 8.5  12 28  Volts
Operating Current   22   mA Note 1
Operating Temp Range -40    85  ºC
Storage Temp Range -40    85  ºC
Reverse Polarity Protection -30      Volts
Measurements
Bridge Excitation 4.9  5.1  Volts
Bridge Impedance 350  1000  5000  Ohms
Bridge Sensitivity 0.5  2.5  150  mV/V Note 2
Output Voltage Range 0.1   +5.1 Volts
Output Load 5000     Ohms
Band Width DC   1000  Hz
Zero Adjustment   ±2   %FR
Span Adjustment   ±8   %FR
Linearity   0.02   %FR
Zero Temp Stability H   0.0004  0.0015  ±%FR/ºC
Span Temp Stability H   0.002  0.0051  ±%FR/ºC

ICA3H ±10 V

Electrical & Environmental
Supply Voltage Range ±13 ±14 ±15 Volts
Operating Current   22   mA Note 1
Operating Temp Range -40    85  ºC
Storage Temp Range -40    85  ºC
Reverse Polarity Protection -30     Volts
Measurements
Bridge Excitation 4.9  5.1  Volts
Bridge Impedance 350  1000  5000  Ohms
Bridge Sensitivity 0.5  2.5  150  mV/V Note 2
Output Voltage Range -10    +10  Volts
Output Load 5000      Ohms
Band Width DC   1000  Hz
Zero Adjustment   ±2   %FR
Span Adjustment   ±8   %FR
Linearity   0.02   %FR
Zero Temp Stability H   0.0004 0.0015 ±%FR/ºC
Span Temp Stability H   0.002  0.0051  ±%FR/ºC

ICA6H ±10 V

Electrical & Environmental
Supply Voltage Range 14 15 18  Volts Note 3
Operating Current   30    mA Note 1
Operating Temp Range -40    85  ºC
Storage Temp Range -40    85  ºC
Reverse Polarity Protection -30     Volts
Measurements
Bridge Excitation 4.9 5.1  Volts
Bridge Impedance 350  1000  5000  Ohms
Bridge Sensitivity 0.5  2.5  150  mV/V Note 2
Output Voltage Range -10    +10  Volts
Output Load 5000     Ohms
Band Width DC   1000  Hz
Zero Adjustment   ±2   %FR
Span Adjustment   ±8   %FR
Linearity   0.02    %FR
Zero Temp Stability H   0.0004  0.0015  ±%FR/ºC
Span Temp Stability H   0.002  0.0051 ±%FR/ºC

ICA4H, ICA5S Current Output Amplifiers

ICA4H 4-20 mA

Electrical & Environmental
Supply Voltage Range 13 24  28  Volts Note 4
Operating Current 26    42  mA Note 1
Operating Temp Range -40    85  ºC
Storage Temp Range -40    85  ºC
Reverse Polarity Protection -30     Volts
Measurements
Bridge Excitation 4.9 5.1  Volts
Bridge Impedance 350  1000  5000  Ohms
Bridge Sensitivity 0.5  2.5  150  mV/V  Note 2
Output Current Range   20  mA
Output Load     1000  Ohms Note 7
Band Width DC   1000  Hz
Zero Adjustment   ±2   %FR
Span Adjustment   ±8   %FR
Linearity   0.02    %FR
Zero Temp Stability H   0.0004  0.0015  ±%FR/ºC
Span Temp Stability H   0.002  0.0051  ±%FR/ºC

ICA5S 4-20 mA

Electrical & Environmental
Supply voltage Range 7.5 24 28 Volts
Operating Current   20  mA (2 wire)
Operating Temp Range -40    85  ºC
Storage Temp Range -40    85 ºC
Reverse Polarity Protection -30     Volts
Measurements
Bridge Excitation 1.05  1.11  1.16  Volts Note 5
Bridge Impedance 350  1000  5000  Ohms Note 6
Bridge Sensitivity 0.5  2.5  55  mV/V Note 2
Output Current Range   20  mA
Output Load     800  Ohms
Band Width DC   1000  Hz
Zero Adjustment   ±2   %FR Note 5
Span Adjustment   ±8   %FR
Linearity   0.02   %FR
Zero Temp Stability S   0.001  0.005  ±%FR/ºC
Span Temp Stability S   0.007  0.014  ±%FR/ºC
Notes

Note 1 - With 350 Ohm load cell connected.
Note 2 - Factory setting is the typical value shown. For other values fit an alternative calibration resistor (see manuals in Downloads tab).
Note 3 - ICA6 maximum voltage can be increased to 24V with a 1000 Ohm load cell.
Note 4 - The ICA4 can tolerate a lower supply voltage if the output load is reduced e.g. operation is possible at 8V provided that the load does not exceed 150 Ohm.
Note 5 - ICA5 with 1000 Ohms load cell connected.
Note 6 - ICA5 recommended bridge impedance is 1000 Ohms or greater.
Note 7 - 24V minimum supply / sink mode

General Notes The voltage between either of the power supply connections and the load cell shield should not exceed 50V. Any leakage will be greater than 10M Ohms.
FR = Full Range
Environmental    
Storage Temperature -40 to +85ºC
Operating Temperature -40 to +85ºC
Relative Humidity 95% maximum non condensing 
CE Environmental Approvals European EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC
<ICA Dimensions

Documents

  • ICA H & S Product Sheet : Miniature Strain Gauge Signal Conditioner, Converts Load Cell to 4-20mA & 0-10V (ICA S & H)
  • ICA H & S Manual : Complete Range of ICA's Strain Gauge or Load Cell Embedded Analogue Amplifier
  • ICA1&2 S & H Manual : ICA1 & ICA2 S and H Versions Strain Gauge or Load Cell Embedded Analogue Amplifier
  • ICA3&6 S & H Manual : ICA3 & ICA6 S and H Versions Strain Gauge or Load Cell Embedded Analogue Amplifier
  • ICA4 S & H Manual : ICA4 S and H Versions Strain Gauge or Load Cell Embedded Analogue Amplifier
  • ICA5 S & A Manual : ICA5 S and H Versions Strain Gauge or Load Cell Embedded Analogue Amplifier
  • ICA6 Solidworks : ICA6 Version Strain Gauge or Load Cell Embedded Analogue Amplifier
Q: How many load cells can you attach to a ICA?

A: One

ICA H
ICA H
Weight:0.13
ICA H | Very High Stability
Price: $80.00
ICA S
ICA 5S
SKU:ICA-5S
Weight:0.13
ICA 5S | Industrial Stability | 2 Wire 4-20 mA
Price: $210.00
View More Info.- Click NowRequired Items and Optional Accessories...
Loading...